LON I/O components

Intelligent LON I/O components


Filter

Manufacturer:   Category:   Bus:    

Products

Picture Description price without VAT
thumb lumina BE8 Digital input 8port (110008)
8 inputs for installation push buttons or other devices with floating contacts (e.g. window contacts, dew point sensors or occupancy sensors) Sensor functions: Occupancy detection, window monitoring, dew point monitoring power supply via controller
on request
thumb lumina B8 LON Digital input 8port (111008)
LON digital input 8-fold, for 8 potential-free contacts (e.g. window, dew point or presence detectors)
on request
thumb LON-Digital input 10port (contact, voltage) (01000-LF-DI10-IP65)
The LF-DI10-IP65 LON is suitable for detecting potential-free switch states, for example electrical limit switches on vent valves or auxiliary contacts of power contractors, push buttons, window contacts, dew point sensors, occupancy sensors. TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Digital input 4port (contact, voltage) (01000-LF-DI4)
LF-DI4 LON is suitable for detecting potential-free switch states, for example electrical limit switches on vent valves or auxiliary contacts of power con- tactors. The input terminals 1 to 4 are wired with the C2 terminals to potential-free switches or contacts. TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC,
on request
thumb LON-Digital input 10port (contact, voltage) (1108511319)
The LF-DI10 LON is suitable for detecting potential-free switch states, for example electrical limit switches on vent valves or auxiliary contacts of power contractors, push buttons, window contacts, dew point sensors, occupancy sensors. TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Digital input 4port (230V) (01000-LF-DI230)
The LF-DI230 LON is suitable for detecting 230 V AC switch states, for example, switches or buttons for light control. The input terminals 1L to 4L are wired with 1N to 4N terminals to 230 V AC via switches or contacts. TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), supply voltage 20 V to 28 V AC/DC
on request
thumb LON-4 S0 inputs (DIN EN 62053-31) (01000-LF-SI4)
The LF-SI4 LON is suitable for counting S0 counter pulses. The software contains the LONMARK profile 2201-10 utility meter. This allows very good integration of the module into a LON-based energy controlling system. For each channel, the module saves up to 500 data records consisting of counter pulses and time stamps by means of a real-time clock (RTC). This makes it possible to use the LF-SI4 also as data logger. In case of a power failure, the data records remain saved. TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Analogue input 4port (current, voltage) (01000-LF-CI4)
LF-CI4 LON analogue sensor module with 4 current or 4 voltage inputs for active 0-20 mA and 0-10V sensors (temperature, electrical vent, valve positions, window monitoring, dewpoint monitoring). TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Analogue input 8port (resistance, voltage) (01000-LF-AI8)
LF-AI8 LON analogue input for passive temperature sensors (Pt1000, Ni1000, NTC) and other resistances and active 0-10V sensors (temperature, electrical vent, valve positions, window monitoring, dewpoint monitoring). TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Mixed (digital in, digital out 16A) (01000-LF-DIO4-2)
LF-DIO4/2 LON sensor/actuator module with 4 digital inputs (for example for light switches and window contacts in a room) and 2 relay outputs for switching two light strips or controlling louvers. It can also be used to control 2 motorized fire dampers. TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Mixed (digital in, digital out 10A) (01000-LF-DIO4-2-IP65)
LF-DIO4/2-IP65 LON sensor/actuator module with 4 digital inputs (for example for light switches and window contacts in a room) and 2 relay outputs for switching two light strips or controlling louvers. It can also be used to control 2 motorized fire dampers. TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Mixed (digital in, digital out 6A and 100 mA) (01000-DM44)
LF-DM4/4 LON sensor/actuator module with 4 digital inputs (for example for light switches and window contacts in a room) and 2 relay outputs and 2 digital outputs for switching two light strips. It can also be used to control motorized fire dampers. TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC With strong inductive loads, it's recommended to protect the relay contacts additionally with an RC element.
on request
thumb LON-Mixed (digital in, digital out one and two-level) (01000-LF-TP)
LF-TP LON sensor/actuator module with 6 digital inputs (for example electrical limit switches on vent valves or auxiliary contacts of power contractors, push buttons, window contacts, dew point sensors, occupancy sensors) and 2 two-level relay outputs for switching multi-level pumps, fans, burners or similar and 2 digital outputs (2 SPST-NO, photoMOS relay). It can also be used for controlling louvers. TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Mixed (In/out voltage, digital out 100 mA) (01000-LF-AM2-4)
LF-AM2/4 LON sensor/actuator module with 2 voltage inputs for active 0-10V sensors (temperature, electrical vent, valve positions, window monitoring, dewpoint monitoring), 2 voltage outputs 0-10V (controlling of motorized vent valves, electronic ballasts) and 2 digital outputs (2 SPST-NO, photoMOS relay). TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Mixed (analog in, digital out triac) (01000-LF-TI-IP65LON)
LF-TI-IP65 LON sensor/actuator module with 4 universal inputs and 4 digital outputs was developed for decentralized switching tasks like climate control (Spatial Axis). It is suitable for detecting temperatures or voltages or for switching 4 thermal valve drives with triacs. TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Output (digital out Triac 0.8A) (01000-LF-TO4LON)
LF-TO4 LON actuator module with 4 digital outputs (Triac 0.8A) for switching switching electrical components, such as relays, contactors, HLK valves etc. TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Output (digital out 5A) (01000-LF-DO4LON)
LF-DO4 LON actuator module with 4 relay outputs (changeover contacts) for switching motors, contactors, lamps, louvers, etc. TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Output (digital out 10A) (01000-LF-DO4-IP65LON)
LF-DO4 LON actuator module with 4 relay outputs (changeover contacts) for switching motors, contactors, lamps, louvers, etc. TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Analogue Output 4port (voltage) (01000-LF-AOP4)
LF-AOP4 LON with 4 analog 0-10 V outputs (for electrical vent and mixing valves, valve positions, etc.). TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb LON-Analogue Output 4port (voltage) (01000-LF-AO4-IP65)
LF-AO4-IP65 LON with 4 analog 0-10 V outputs (for electrical vent and mixing valves, valve positions, etc.). TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Supply voltage 20 V to 28 V AC/DC
on request
thumb iLC Light Controller - Europe (80012R)
iLC Outdoor Lighting Controller, C-Band Power line Transceiver (ISO/IEC 14908-3), Input Voltage: 110 VAC to 250 VAC (2 Wire), 1x Switched internal relay for turning lights on/off (max 4A), 1x Analog Output: 0-10V or 1x DALI bus master interface for max. 4 ballasts, 1x Digital Input (e.g. for Occupancy sensors)
on request
thumb LON-Powerline (Meter, Digital Out 10A) (095260)
BIALON PowerHouse meter with one relay output for electrical devices with current ratings up to 10A. Intended for installation in a recessed socket. Measurement of the electrical energy W, electrical power (active power, reactive power, and apparent power), effective current and voltage, power factor cos φ and grid frequency with an accuracy class of A, (2%) as per DIN EN 50470-1 and -3. LON Powerline interface as per DIN EN 14908-3 or ISO/IEC 14908-3. Supply voltage 90-260V~/50-60Hz
on request
thumb LON Powerline Digital input 2port (5V) (02000-SM2-ST05-H02)
SM2 LON sensor module with 2 digital inputs (internal 5V) which can be connected to one 2-gang switch/push button or to two separate switches/push buttons. Intented for installation in a recessed socket. LON Powerline C-Band interface as per DIN EN 14908-3 or ISO/IEC 14908-3. Supply voltage 230V~/50Hz
on request
thumb LON Powerline Digital input 3port (5V) (02000-SM3-ST02-H02)
SM3 LON sensor module with 3 digital inputs (internal 5V) which can be connected to a 2-gang or 3-gang switch (Blind, Shutter: Up, Down, Stop). Centralized switching functionality (Master-On, Master-Off) can also be implemented with SM3. Intented for installation in a recessed socket. LON Powerline C-Band interface as per DIN EN 14908-3 or ISO/IEC 14908-3. Supply voltage 230V~/50Hz
on request
thumb LON Powerline Mixed (digital in 15V, digital out 3A) (02000-SAM2-ST01-H01)
SAM2 LON sensor/actuator module with 2 digital inputs for a blind-control switch and 2 interlocked outputs for motors with current ratings up to 3A. Intented for installation in a recessed socket. LON Powerline C-Band interface as per DIN EN 14908-3 or ISO/IEC 14908-3. Supply voltage 230V~/50Hz
on request
thumb LON Powerline Mixed (digital in 230V, digital out 10A) (02000-SAM1L-ST01-H01)
SAM1L LON sensor/actuator module with one 230V digital input and one switched output for loads up to 10A. The input can be connected to a light switch or to other switching elements (e.g. motion detector, thermostat etc..). Intented for installation in a recessed socket. LON Powerline C-Band interface as per DIN EN 14908-3 or ISO/IEC 14908-3. Supply voltage 230V~/50Hz
on request
thumb LON Powerline Mixed (Digital In 230V, Dimming Output 300W) (02000-SAMDR-ST01-H01)
SAMDR LON sensor/dimmer module with one 230V input and a triac-switched output for electrical devices up to 300W. Loads up to 150W are allowed when the actuator is used with universal electronic transformers (leading and trailing edge). Intented for installation in a recessed socket. LON Powerline interface as per DIN EN 14908-3 or ISO/IEC 14908-3. Supply voltage 230V~/50Hz
on request
thumb LON Powerline Digital Out (10A) (02000-AM1C-ST01-H01)
AM1C LON actuator module with 1 relay-switched output for electrical devices with current ratings up to 10A with additional current measurement feature. Intented for installation in a recessed socket. LON Powerline interface as per DIN EN 14908-3 or ISO/IEC 14908-3. Supply voltage 230V~/50Hz
on request
thumb LON Powerline Analog Out (1-10V) (02000-AMD10V-ST03-H01)
AMD10V LON actuator module with analog 0-10 V output to switch and / or dim electronic ballasts or other devices with a 1-10V interface. This actuator has a current sink of max. 50 mA and can switch up to 6 electronic ballasts connected in parallel. Intented for installation in a recessed socket. LON Powerline interface as per DIN EN 14908-3 or ISO/IEC 14908-3. Supply voltage 230V~/50Hz
on request
thumb EWIO-9180-M (110910)
High performance M-Bus data logger , among others for functions in energy management and energy controlling. M-Bus Master for 80 M-Bus loads, 4 digital inputs (for example for light switches and window contacts in a room), 4 S0, and 8 outputs 5A for switching two light strips or controlling louvers. 2 analog inputs (0-10V, resistance) and 2 analog outputs (0-10V). Input voltage 24V DC, +-10%
on request
thumb BIALON (PLC) Mixed-4S02R 230Vac (095004)
LON 4 S0 impulse counter, 2 relay outputs 16A, DIN rail, C-Band Power line Transceiver (ISO/IEC 14908-3), Internal Coupling, Power supply 110V to 250V
on request
thumb BIALON (FTT) Mixed-4S02R 230Vac (095002)
LON 4 S0 impulse counter, 2 relay outputs 16A, DIN rail, C-Band Power line Transceiver (ISO/IEC 14908-3), Internal Coupling, Power supply 110V to 250V
on request
thumb BIALON (FTT) Mixed-4S02R 24Vac/dc (095008)
LON 4 S0 impulse counter, 2 relay outputs 16A, DIN rail, C-Band Power line Transceiver (ISO/IEC 14908-3), Internal Coupling, Power supply 110V to 250V
on request
thumb BIALON (FTT) Input-10S0 230Vac (095001)
LON 10 x S0 impulse counter, DIN rail, LonWorks TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Power supply 110V to 250V
on request
thumb BIALON (FTT) Input-10S0 24Vac (095007)
LON 10 x S0 impulse counter, DIN rail, LonWorks TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Power supply 20V to 24Vac/dc
on request
thumb BIALON (PLC) Input-10S0 230Vac (095003)
LON 10 x S0 impulse counter, DIN rail, C-Band Power line Transceiver (ISO/IEC 14908-3), Internal Coupling, Power supply 110V to 250V
on request