Cold and Heat meter (Qn 0,6 - 1000 m³/h)

LON, M-Bus and Wireless M-Bus ultrasonic split heat meter, MID approval.


Description

Ultrasonic heat meters have, unlike mechanical heat meters, no moving parts in the measuring tube and have therefore almost no wear. Ultrasonic heat meters also have a much lower pressure drop. The installation position is almost infinitely and depending on the type ultrasonic heat meters do not rrequire inlet and outlet lines.

Specification

Type Ultrasonic
Voltage (U) Battery service life 10 years wall mounted
Battery service life 8 years mounted on flow sensor
or mains supply at 230 V AC or 24 V AC
Media Temperature 15 ... 130 °C
Ambient Temperature 0 ... +55 °C
Installation Position horizontal, vertical

Products

Picture Description price without VAT
thumb MULTICAL 603 Cold and Heat meter (Qn 0,6 - 1000 m³/h)
Ultrasonic split heat meter retrofittable with BACnet, LON, M-Bus, Wireless M-Bus and Pulse modules, MID approval.
on request
thumb MULTICAL 602 Cold and Heat meter (Qn 0,6 - 1000 m³/h)
Ultrasonic split heat meter retrofittable with LON, M-Bus, Wireless M-Bus and Pulse modules, MID approval.
on request
thumb M602-LON-in Module (297548)
LON module for the adaption of of WZ-Multical 602 heat meters to the LON system, Neuron FT 5000 - TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Powered by meter supply, In addition it provides an pulse input S0 in accordance with DIN 43864, Temperature range 5..55 °C,
on request
thumb M602-M-Bus-in Module (297545)
M-Bus module for the adaption of of WZ-Multical 602 heat meters to the M-Bus system, M-Bus interface EN 13757-2, -3, In addition it provides an pulse input S0 in accordance with DIN 43864, Temperature range 5..55 °C,
on request
thumb M602 Wireless M-BUS (297555)
Wireless M-Bus module for the adaption of WZ-Multical 602 heat meters to the M-Bus system, 868 MHz, Unidirectional radio link, Wireless M-Bus (Conform to OMS), Selectable operation modes: C1
on request
thumb M403/603-Data-in Module (297101)
Data pulse modules for the adaption of of WZ-Multical 403 and 603 heat meters to the M-Bus system, protocol Kamstrup KMP (1200 bit/s), two pulse inputs for additional water and electricity meters, Temperature range 5..55 °C,
on request
thumb M403/603-M-Bus-in Module (297102)
M-Bus module for the adaption of of WZ-Multical 403 and 603 heat meters to the M-Bus system, M-Bus interface EN 13757-2, -3, two pulse inputs for additional water and electricity meters, Temperature range 5..55 °C,
on request
thumb M403/603-M-Bus-out Module (297103)
M-Bus module for the adaption of of WZ-Multical 403 and 603 heat meters to the M-Bus system, M-Bus interface EN 13757-2, -3, Two pulse outputs for selected operations, Temperature range 5..55 °C,
on request
thumb M403/603 Wireless M-BUS Input (297104)
Wireless M-Bus module for the adaption of WZ-Multical 403/603 heat meters to the M-Bus system, 868 MHz, Unidirectional radio link, Wireless M-Bus (Conform to OMS), Selectable operation modes: C1 two pulse inputs for additional water and electricity meters,
on request
thumb M403/603 Wireless M-BUS Output (297105)
Wireless M-Bus module for the adaption of WZ-Multical 403/603 heat meters to the M-Bus system, 868 MHz, Unidirectional radio link, Wireless M-Bus (Conform to OMS), Selectable operation modes: C1, Two pulse outputs for selected operations
on request
thumb M403/603 Analog Output Module (297106)
Analog Output Module for the WZ-Multical 403/603 heat meters, Two current outputs selectable as either 0...20 mA or 4...20 mA
on request
thumb M403/603-Modbus-in Module (297107)
Modbus module for the adaption of of WZ-Multical 403 and 603 heat meters to the Modbus system, Modbus RTU communication (up to 115200 bits/s), two pulse inputs for additional water and electricity meters, Temperature range 5..55 °C,
on request
thumb M403/603-LON-in Module (297108)
LON module for the adaption of of WZ-Multical 403 and 603 heat meters to the LON system, TP/FT-10 free topology twisted pair (ISO/IEC 14908-2), Powered by meter supply, In addition it provides an pulse input S0 in accordance with DIN 43864, Temperature range 5..55 °C
on request
thumb M403/603-BACnet MS/TP-in Module (297109)
BACnet MS/TP module for the adaption of of WZ-Multical 403 and 603 heat meters to the BACnet system, BACnet MS/TP communication (up to 115200 bits/s), two pulse inputs for additional water and electricity meters, Temperature range 5..55 °C