BACnet I/O components

Intelligent BACnet I/O components


Specification

Manufacturer METZ Connect
Bus BACnet MS/TP

Filter

Category:    

Products

Picture Description price without VAT
thumb BACnet MS/TP-Digital input 4port (contact, voltage) (01200-BMT-DI4-BAC_MS-TP)
The BMT-DI4 BACnet MS/TP is suitable for detecting potential-free switch states, for example electrical limit switches on vent valves or auxiliary contacts of power contactors. The inputs can be operated by means of potential-free switches or contacts or used as voltage inputs. BACnet MS/TP, RS485 (two-wire bus), Supply voltage 20 V to 28 V AC/DC
on request
thumb BACnet MS/TP-Digital input 4port (contact, voltage) (01200-BMT-DI4-IP65-BAC_MS-TP)
The BMT-DI4 IP65 BACnet MS/TP is suitable for detecting potential-free switch states, for example electrical limit switches on vent valves or auxiliary contacts of power contactors. TThe inputs can be operated by means of potential-free switches or contacts or used as voltage inputs. BACnet MS/TP, RS485 (two-wire bus), Supply voltage 20 V to 28 V AC/DC
on request
thumb BACnet MS/TP-Digital input 10port (contact, voltage) (01200-BMT-DI10-BAC_MS-TP)
The BMT-DI10 BACnet MS/TP is suitable for detecting potential-free switch states, for example electrical limit switches on vent valves or auxiliary contacts of power contractors, push buttons, window contacts, dew point sensors, occupancy sensors. BACnet MS/TP, RS485 (two-wire bus), Supply voltage 20 V to 28 V AC/DC, Supply voltage 20 V to 28 V AC/DC
on request
thumb BACnet MS/TP-4 S0 inputs (DIN EN 62053-31) (01200-BMT-SI4-BAC_MS-TP)
The BMT-SI4 BACnet MS/TP with 4 S0 inputs to DIN EN 62053-31 class A is suitable for counting S0 counter pulses. This allows very good integration of the module into an energy controlling system. In case of a power failure, the last counter readings are saved. The inputs can be scanned by means of standard objects via a BACnet client. BACnet MS/TP, RS485 (two-wire bus), Supply voltage 20 V to 28 V AC/DC
on request
thumb BACnet MS/TP-Analogue input 8port (resistance, voltage) (01200-BMT-AI8-BAC_MS-TP)
BMT-AI8 BACnet MS/TP analogue input for passive temperature sensors (Pt1000, Ni1000, NTC) and other resistances and active 0-10V sensors (temperature, electrical vent, valve positions, window monitoring, dewpoint monitoring). he inputs can be configured universally by means of standard objects via a BACnet client. BACnet MS/TP, RS485 (two-wire bus), Supply voltage 20 V to 28 V AC/DC
on request
thumb BACnet MS/TP-Mixed (digital in, digital out 16A) (01200-BMT-DIO4-2-BAC_MS-TP)
BMT-DIO4/2 BACnet MS/TP sensor/actuator module with 4 digital inputs (for example for light switches and window contacts in a room) and 2 relay outputs for switching two light strips or controlling louvers. It can also be used to control 2 motorized fire dampers. BACnet MS/TP, RS485 (two-wire bus), Supply voltage 20 V to 28 V AC/DC
on request
thumb BACnet MS/TP-Mixed (digital in, digital out 10A) (01200-BMT-DIO4-2-IP65-BAC_MS-TP)
BMT-DIO4/2 IP65 BACnet MS/TP sensor/actuator module with 4 digital inputs (for example for light switches and window contacts in a room) and 2 relay outputs for switching two light strips or controlling louvers. It can also be used to control 2 motorized fire dampers. BACnet MS/TP, RS485 (two-wire bus), Supply voltage 20 V to 28 V AC/DC
on request
thumb BACnet MS/TP-Modul (digital in, digital out 8A) (01200-BMT-DIO4-2-IP230-BAC_MS-TP)
BMT-DIO4/2 IP 230 BACnet MS/TP module in IP65 housing with 4 digital inputs (for example for light switches and window contacts in a room) and 2 digital outputs (Relais 8A per Relais) for switching two light strips or controlling louvers. It can also be used to control 2 motorized fire dampers. BACnet MS/TP, RS485 (two-wire bus), Supply voltage 230V AC
on request
thumb BACnet MS/TP-Mixed (digital in, digital out one and two-level) (01200-BMT-TP-BAC_MS-TP)
BMT-TP BACnet MS/TP sensor/actuator module with 6 digital inputs (for example electrical limit switches on vent valves or auxiliary contacts of power contractors, push buttons, window contacts, dew point sensors, occupancy sensors) and 2 two-level relay outputs for switching multi-level pumps, fans, burners or similar and 2 digital outputs (2 SPST-NO, photoMOS relay). It can also be used for controlling louvers. BACnet MS/TP, RS485 (two-wire bus), Supply voltage 20 V to 28 V AC/DC
on request
thumb BACnet MS/TP-Output (digital out Triac 0.8A) (01200-BMT-TO4-BAC_MS-TP)
BMT-TO4 BACnet MS/TP actuator module with 4 digital outputs (Triac 0.8A) for switching switching electrical components, such as relays, contactors, HLK valves etc. BACnet MS/TP, RS485 (two-wire bus), Supply voltage 20 V to 28 V AC/DC
on request
thumb BACnet MS/TP-Output (digital out 5A) (01200-BMT-DO4-BAC_MS-TP)
BMT-DO4 BACnet MS/TP actuator module with 4 relay outputs (changeover contacts) for switching motors, contactors, lamps, louvers, etc. BACnet MS/TP, RS485 (two-wire bus), Supply voltage 20 V to 28 V AC/DC
on request
thumb BACnet MS/TP-Analogue Output 4port (voltage) (01200-BMT-AO4-BAC_MS-TP)
BMT-AO4 BACnet MS/TP with 4 analog 0-10 V outputs for electrical vent and mixing valves, valve positions, etc. BACnet MS/TP, RS485 (two-wire bus), Supply voltage 20 V to 28 V AC/DC
on request
thumb BACnet MS/TP-Analogue Output 4port (voltage) (01200-BMT-AOP4-BAC_MS-TP)
BMT-AO4 BACnet MS/TP with 4 analog 0-10 V outputs (for electrical vent and mixing valves, valve positions, etc.). Each output can be set for automatic or manual operation by means of 4 potentiometers at the front. BACnet MS/TP, RS485 (two-wire bus), Supply voltage 20 V to 28 V AC/DC
on request