Innovative products for professional Outdoor and Streetlighting applications
Picture | Description | price without VAT |
---|---|---|
outdoor LED lamp LED lamp for outdoor use that is highly cost-effective. The robust diecast aluminium housing with its finned surface guarantees excellent heat management. Being certified to insulation class IP 67, this lamp also functions even under extreme ambient conditions and meets the toughest safety standards. |
on request
|
|
SmartServer 2.2 PL Protocol Gateway between M-Bus, Modbus RTU, Modbus TCP/IP and LonWorks Powerline (>1000 data points). |
on request
|
|
CPD 3000 Light Controller - Europe (76610R) CPD 3000 Outdoor Lighting Controller, C-Band Power line Transceiver (ISO/IEC 14908-3), Input Voltage: 100 VAC to 250 VAC (2 Wire + Earth) Switched internal relay for turning lights on/off (max 500W) 1x Analog Output 0-10V |
on request
|
|
I-PLC 25.55 Light Controller - Europe (80010R) I-PLC 25.55 Outdoor Lighting Controller, C-Band Power line Transceiver (ISO/IEC 14908-3), Input Voltage: 195 VAC to 250 VAC (2 Wire + Earth), Switched internal relay for turning lights on/off (max 600W), 1x Analog Output: 0-10V, 1x Digital Input (e.g. for Occupancy sensors) |
on request
|
|
iLC Light Controller - Europe (80012R) iLC Outdoor Lighting Controller, C-Band Power line Transceiver (ISO/IEC 14908-3), Input Voltage: 110 VAC to 250 VAC (2 Wire), 1x Switched internal relay for turning lights on/off (max 4A), 1x Analog Output: 0-10V or 1x DALI bus master interface for max. 4 ballasts, 1x Digital Input (e.g. for Occupancy sensors) |
on request
|
|
GLC AO Light Controller - Europe (60112R) GLC AO Outdoor Lighting Controller, C-Band Power line Transceiver (ISO/IEC 14908-3), Input Voltage: 230 VAC (2 Wire), 1x Analog Output: 0-10V 1x Digital Input (e.g. for Occupancy sensors) 1x Digital Output (max 400W) |
on request
|
|
GLC Dali Light Controller - Europe (60114R) GLC Dali Outdoor Lighting Controller, C-Band Power line Transceiver (ISO/IEC 14908-3), Input Voltage: 230 VAC (2 Wire), 1x DALI bus master interface (broadcast) 1x Digital Input (e.g. for Occupancy sensors) 1x Digital Output (max 400W) |
on request
|
|
iPC Light Controller - Europe (80013R) iPC Outdoor Pole Controller, C-Band Power line Transceiver (ISO/IEC 14908-3), Input Voltage: 110 VAC to 250 VAC (2 Wire), 1x Switched internal relay for turning lights on/off (max 4A), 1x Analog Output: 0-10V or 1x DALI bus master interface for max. 4 ballasts, 1x Digital Input (e.g. for Occupancy sensors) |
on request
|
|
iLUX - intelligent Lux Meter (80050R) iLUX - intelligent Lux Meter, Moisture-proof, Sensor unit protected by opal glass, Connection cable to the controller: 10 m plus iPC-LUX Outdoor Pole Controller, Input Voltage: 200 VAC to 250 VAC (2 Wire), 1x Switched internal relay for turning lights on/off (max 4A), 1x Analog Output: 0-10V or 1x DALI bus master interface for max. 4 ballasts, 1x connector for iLUX |
on request
|
|
Observer 220° (80001R) Observer 220° with digital signal evaluation, Moisture-proof, Sensor head adjustable in 2 axes, Short-time operation to control signal encoders, High protection against ambient light |
on request
|
|
CRD 3000 Street Light Bridge (76520R) Power Line/RF Bridge, C-Band Power line Transceiver (ISO/IEC 14908-3), Input Voltage: 100 VAC to 250 VAC (2 Wire + Earth) |
on request
|
|
BIALON NF-02 (095027) Network filter for LONWORKS Powerline networks (B-Band (110 kHz) and C-Band (132kHz)). Improves the network quality by suppressing high-frequency interference signals. Attenuates the interference signal by 6 dB. This attenuation filter can be installed in lamps, distribution boxes, sockets, etc. |
on request
|
|
BIALON NF-01 (095026) Network filter for LONWORKS Powerline networks (B-Band (110 kHz) and C-Band (132kHz)). Improves the network quality by suppressing high-frequency interference signals. Attenuates the interference signal by 6 dB. The attenuation filter is installed on a DIN top-hat rail as per EN 50022. |
on request
|
|
BIALON FF-01 (095025) Band elimination filter for LONWORKS Powerline networks, B-Band (110 kHz) and C-Band (132kHz). Protects against active and passive interference sources and prevents transmission beyond site borders. For separation of neighbouring communication groups. |
on request
|
|
BIALON PC-02 (095020) Phase coupler to improve data transfers in LONWORKS Powerline networks (B-Band (110 kHz) and C-Band (132kHz)) |
on request
|
|
BIALON PC-04 (095029) 3-Phase Powerline carrier signal coupler to improve data transfers in LONWORKS Powerline networks, B-Band (110 kHz) and C-Band (132kHz) Couples the payload signal into the 230V power network |
on request
|
|
Phase Coupler C-Band (72103A-3PC) 3-Phase powerline carrier signal coupler to improve data transfers in LONWORKS Powerline networks, B-Band (110 kHz) and C-Band (132kHz) |
on request
|
|
PLCA-22 Powerline Network Analyzer (58022-2) Power line communication test tool. Analyzes power line signaling performance and signal margin of the PLT-22 power line transceiver. Helps to identify if routers, conditioning devices or booster amplifiers are needed. Determines power circuit phase. RS-232 port for data logging. Power requirements Internal 100-120 VAC/240 VA |
on request
|